CLIA Kit for Aldosterone (ALD)

Product Code:
 
CCA911Ge
Product Group:
 
CLIA Kits
Supplier:
 
Cloud-Clone Corp.
Regulatory Status:
 
RUO
Application:
 
Chemiluminescent Immunoassay (CLIA)
1 / 1

No additional charges, what you see is what you pay! *

CodeSizePrice
CCA911Ge-24T24T£285.00
Quantity:
CCA911Ge-48T48T£475.00
Quantity:
CCA911Ge-96T96T£666.00
Quantity:
CCA911Ge-96T*596T*5£2,889.00
Quantity:
CCA911Ge-96T*1096T*10£5,429.00
Quantity:
Prices exclude any Taxes / VAT
Stay in control of your spending. These prices have no additional charges, not even shipping!
* Rare exceptions are clearly labelled (only 0.14% of items!).
Multibuy discounts available! Contact us to find what you can save.
This product comes from: China.
Typical lead time: 14-21 working days.
Contact us for more accurate information.
  • Further Information
  • Documents
  • Show All

Further Information

Assay length:
2h
Assay procedure summary:
1. Prepare all reagents, samples and standards;
2. Add 50µL standard or sample to each well.
    And then add 50µL prepared Detection Reagent A immediately.
    Shake and mix. Incubate 1 hour at 37°C;
3. Aspirate and wash 3 times;
4. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
5. Aspirate and wash 5 times;
6. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;
7. Read RLU value immediately.
Detection range:
7.81-2,000pg/mL
Method:
Competitive Inhibition
Organism species:
Pan-species (General)
Precision:

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Aldosterone (ALD) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Aldosterone (ALD) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Sample type:
serum, plasma and other biological fluids
Sensitivity:
The minimum detectable dose of this kit is typically less than 2.93pg/mL
Specificity:

This assay has high sensitivity and excellent specificity for detection of Aldosterone (ALD).
No significant cross-reactivity or interference between Aldosterone (ALD) and analogues was observed.

Stability:

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Test principle:
The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Aldosterone (ALD). A competitive inhibition reaction is launched between biotin labeled Aldosterone (ALD) and unlabeled Aldosterone (ALD) (Standards or samples) with the pre-coated antibody specific to Aldosterone (ALD). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Aldosterone (ALD) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Aldosterone (ALD) level in the sample or standard.

Documents